TM 9-2320-366-34-3
17-16
Change 2
17-3.
M1090/M1094 FOUR-WAY RELIEF VALVE REPLACEMENT/REPAIR (CONT)
(9)
Start engine (TM 9-2320-366-10-1).
(10) Position PTO switch to ON (TM 9-2320-366-10-1).
(11) Increase engine speed to 1250-1450 RPM (TM 9-
2320-366-10-1).
(12) Attach a temperature indicator label to hydraulic
reservoir (11).
(13) Press and hold DUMP BED UP/DOWN switch to the
UP position until hydraulic oil temperature reaches
140-160
F (60-70 C).
CAUTION
Hydraulic oil temperature must be 140-
160
F (60-70 C) prior to performing
troubleshooting checks.
Failure to comply
may result in inaccurate test results.
NOTE
•
Holding DUMP BED UP/DOWN switch in
the UP position will force hydraulic oil
through relief valve and cause oil
temperature to rise.
•
Measure hydraulic oil temperature near
bottom of hydraulic reservoir.
•
Steps (16) through (24) require the aid of
an assistant.