TEST EQUIPMENT SETUP FOR CONTINUITY AND RESISTANCE TESTS 91 AND 92 - Continued.
J5 CONNECTOR
ICE BOX
DC OUTPUT
CABLE
W1 CABLE
J1 CONNECTOR
RED
LEAD
POWER
SWITCH
DCA
CONNECTOR
W1 CABLE
BLACK
LEAD
AC INPUT
DC INPUT
FUSE
POWER
CONVERTER
110 VAC
SUPPLY CABLE
Figure 29.
MSD/ICE Power Setup.
6. Connect 110 vac supply cable or NATO slave cable to power converter.
7. Connect W1 cable to J1 connector on ICE BOX and to vehicle DCA connector.
8. Push ICE Box circuit breaker button to ON position.
9. Return to troubleshooting procedure.
END OF TASK
Multimeter Setup
1. Select appropriate scale for required reading.
TM 9-2330-342-23&P
0004
0004-20