TM-9-2330-342-23-P

PALLETIZED LOAD SYSTEM TRAILER (PLST) M1076 A1

TECHNICAL MANUAL; FIELD MANUAL

OCTOBER 2012

  TM-9-2330-342-23-P - Page 111 of 1348

TEST EQUIPMENT SETUP FOR CONTINUITY AND RESISTANCE TESTS 91 AND 92 - Continued.
ICE BOX
J4
CONNECTOR
BUTTON
PROBE
CABLE
CABLE P1
CONNECTOR
J6 CONNECTOR
J6
CONNECTOR
P1
CONNECTOR
RED
LEAD
BLACK
LEAD
Figure 27.
ICE Box Setup for Continuity and Resistance Test.
2. Connect cable P1 connector to J6 connector on ICE BOX.
CABLE P3
SERIAL PORT
COM2
MSD POWER
PORT
CABLE P2
Figure 28.
MSD Serial and Power Cable Connection.
3. Connect cable P3 connector to serial port (COM2) connector on rear of MSD.
4. Connect cable P2 connector to MSD power port.
5. Connect DC output cable from power converter to J5 connector on ICE BOX.
TM 9-2330-342-23&P
0004
0004-19


Back to Top