TM-9-2330-342-23-P

PALLETIZED LOAD SYSTEM TRAILER (PLST) M1076 A1

TECHNICAL MANUAL; FIELD MANUAL

OCTOBER 2012

  TM-9-2330-342-23-P - Page 385 of 1348

QUICK RELEASE
VALVE
AIR
LINE
2660
TRANSDUCER
Figure 2.
Quick Release Valve and Air Line 2660.
6.
Connect TK test cable to MSD/ICE test equipment (WP
0004) and to the TK pressure transducer (blue stripe).
7.
Perform ICE Offset Test 50.
CONDITION/INDICATION
Does test equipment pass offset test?
DECISION
Yes - Go to (Step 3 - Is load sensing valve adjusted correctly and supplying 30 to 125 ± 5 psi (207-861 ± 34
kPa)?).
No - Test equipment failed offset. Contact your Supervisor.
STEP 3
Is load sensing valve adjusted correctly and supplying 30 to 125 ± 5 psi (207-861 ± 34 kPa)?
WARNING
If air lines are disconnected when they are under 125± 5 psi (862± 34 kPa) pressure, they
can whip around. Care should be exercised when disconnecting an air hose that is thought
to be under pressure. Be sure to wear proper eye protection. Failure to comply may result in
injury or death to personnel.
1.
Disconnect load sensing valve control rod from axle (WP
0080).
2.
Have assistant turn engine start switch to ON. Refer to vehicle Operator's manual (WP
0190).
TM 9-2330-342-23&P
0040
0040-3


Back to Top