QUICK RELEASE
VALVE
AIR
LINE
2660
TRANSDUCER
Figure 3.
Quick Release Valve and Air Line 2660.
3.
Push in trailer charge valve in vehicle. Refer to vehicle Operator's manual (WP
0190).
4.
Perform ICE Test 50.
5.
While assistant fully applies brake pedal, push up on control rod and observe meter. Refer to vehicle Operator's
manual (WP
0190).
6.
Meter should display 125 ± 5 psi (861 ± 34 kPa).
CONDITION/INDICATION
Is load sensing valve adjusted correctly and supplying 30 to 125 ± 5 psi (207-861 ± 34 kPa)?
DECISION
Yes - Go to (Step 4 - Is load sensing valve adjusted correctly and supplying 30 to 125 ± 5 psi (207-861 ± 34
kPa)?).
No - Replace load sensing valve (WP
0080). Go to (Step 7 - Do service brakes apply correctly?) to verify problem
is solved.
STEP 4
Is load sensing valve adjusted correctly and supplying 30 to 125 ± 5 psi (207-861 ± 34 kPa)?
1.
Have assistant turn engine start switch to ON. Refer to vehicle Operator's manual (WP
0190).
2.
Perform ICE Test 50.
QUICK RELEASE
VALVE
AIR
LINE
2660
TRANSDUCER
Figure 4.
Quick Release Valve and Air Line 2660.
TM 9-2330-342-23&P
0040
0040-4