TM 9-2330-356-14
TA099887
Figure 4-157. Deadman Release Valve.
4-95.
Meter Inlet Pressure Gage (Fig. 4-158)
a.
Removal.
(1) Disconnect the nylon tube from tube fitting.
(2) Remove two nuts that secure retaining plates
to rear of gage and remove plates. Then remove gage.
(3) Remove tee and drain cock assembly from
rear of gage.
b.
Installation.
Reverse instructions in step
a.
TA099889
Figure 4-158.
Meter Inlet Pressure Gage.
4-96. Static Reel (Fig. 4-159)
a.
Removal.
(1) Remove two capscrews, four washers, and
two self-locking nuts that secure static reel to cabinet.
(2) Remove static reel from cabinet.
b.
Installation.
(1) Place static reel in cabinet and position
mounting holes.
(2) Install two capscrews, four washers, and two
self-locking nuts.
4-164