TM 9-2330-356-14
includes a precheck valve, load/unload valve, and float
(b)
The fluid raises a float in the float valve
valve (fig. 4-151).
which shuts off fluid flow through port Y (load/unload
(1)
Precheck Valve.
valve must be in a load position).
(c)
With flow shut off, the pressure in the
(a)
In the open position, this valve allows
line to port Y is equalized (fig. 4- 151B). A spring in the
fluid from the inlet of the 4-inch control valve to reach the
4-inch control valve then closes the 4-inch control valve
float valve at port X (fig. 4-151A).
and stops bottom load operation.
Figure 4-147. Dispensing System (M967 and M967A1).
TA502367
4-154