TM 9-2330-356-14
b.
Filtered Fuel Dispensing.
This operation is used to
dispense metered fuel from the semitrailer tank to a
vehicle. Fuel is pumped through the filter/separator, a
meter, and a hose reel to the vehicle (fig. 2-32). Operation
is as follows:
(1) Review instructions in paragraph 2-8.
(2) Ensure that all valves are closed.
(3) Unreel the static reel and connect cable first
to grounding stud, then to vehicle.
(4) Remove fire extinguishers and bring to point
of operation.
(5) Start engine (para 2-10) and when warm
adjust engine speed to 1000-1200 rpm.
(6) Put selector valve E (fig. 2-11) in the
UNLOAD position.
(7) Open valves A (para 2-11f), H, M, and either
P or R, depending on which hose reel is to be used. If both
hose reels are to be used, open both valves P and R. Reset
meter to zero by pushing in the meter reset knob
(fig. 2-14) and turning clockwise.
Figure 2-32. Filtered FueI Dispensing Flow Diagram (M969 and M969A1).
2-35