TM 9-2350-238-20-1
1
2
3
4
5
6
7
8
Install new gasket (1), generator fan guard
(2), tube axial fan (3), and hose clamp (4).
Adjust generator fan guard until it contacts
cover. Place open side of guard inboard.
Connect electrical connector (5) to
receptacle (6) on tube axial fan (3).
Install new duct to bulkhead gasket (7)
and generator air intake duct (8).
Install two flat washers (9), two hexagon
head capscrews (10), and new Iockwire
(11) (item 27, appx C).
Install eight flat washers (12), eight socket
head capscrews (13), and new Iockwire
(14) (item 26, appx C).
Install new elbow to bulkhead gasket (15)
and generator intake duct elbow (16).
Install two flat washers (17), two machine
screws (18 and 19), and new Iockwire (20)
(item 26, appx C).
Install four flat washers (21) and four
socket head capscrews (22).
2-555