TM 9-2350-238-20- 2
2-16. TYPICAL FEMALE-TYPE PLU G
(CONT) .
REASSEMBL Y
1
Strip cable insulation equal to depth o f
solder wells of socket contacts (1) .
2
Slide nut (2) over cable (3) .
3
Slide grommet (4) over cable leads (5) .
4
Insert cable leads (5) into solder wells o f
socket contacts (1) and solder .
5
Push insert (6) into shell assembly (7 )
from rear until seated. Groove (8) in in-
sert (6) must be alined with guide i n
shell assembly (7) to ensure proper fit .
6
Push socket contacts (1) into insert (6 )
from rear until seated .
7
Slide coupling (9) onto shell assembl y
(7) .
8
Push grommet (4) down cable leads (5 )
and over solder wells of socket contacts
(1) .
9
Screw nut (2) onto shell assembly (7) .
2-17. TYPICAL MALE-TYPE PLUG .
DISASSEMBL Y
1
Unscrew nut (1) from shell assembly (2 )
and slide back on cable (3) .
2
Slide grommet (4) back on cable lead s
(5) .
3
Slide coupling (6) off shell assembly (2) .
4
Drive pin contacts (7) out through rear o f
insert (8) with pin extractor .
5
Push insert (8) out through rear of shel l
assembly (2) .
6
Unsolder cable leads (5) from pin con -
tacts (7) .
2-7 0