TM 9-2350-238-34-1
Table 2-1. DIRECT SUPPORT TROUBLESHOOTING (CONT )
MALFUNCTIO N
TEST OR INSPECTIO N
CORRECTIVE ACTIO N
Step 8.
Check for damaged or faulty Iockout cylinder check valve .
If damaged or faulty, replace lockout cylinder check valve. Refer to
TM 9-2350-238-20-1 .
20. HYDRAULIC SUSPENSION LOCKOUT CYLINDER ASSEMBLY DOES NOT LOCK .
Step 1.
Check for leaks and damaged or clogged tubes, hoses, and fittings .
a. Tighten all loose connections .
b. Replace leaking or damaged components. Refer to TM 9-2350-
238-20-1 .
Step 2.
If problem still exists, notify general support maintenance .
21. HYDRAULIC SUSPENSION LOCKOUT CYLINDER ASSEMBLY DOES NOT UNLOCK .
Step1. Check for damaged or faulty lockout cylinder manifold check valve .
If damaged or faulty, replace lockout cylinder manifold check valve.
Refer to TM 9-2350-238-20-1 .
Step 2.
If problem still exists, notify general support maintenance .
SPAD E
22. SPADE DOES NOT RAISE OR LOWER .
Step 7.
Remove rear hydraulic access cover for access to spade hydraulic
components. Refer to TM 9-2350-238-20-1. Check for leaks and damage d
or clogged hoses and fittings.
a. Tighten all loose connections .
b. Replace all leaking or damaged components. Refer to TM 9-
2350-238-20-1 .
2-1 7