TM 9-2350-238-34-1
2-14. TYPICA L FEMALE-TYPE PANEL MOUNTING RECEPTACLE CONNECTOR .
DISASSEMBLY
1
2
3
4
5
Unscrew nut (1) from shell assembly (2) and
slide back on cable (3).
Slide grommet (4) back on cable leads (5).
Drive socket contacts (6) out through front of
insert (7) with pin extractor.
Unsolder lead from socket contacts (6).
Push insect (7) out through rear of shell
assembly (2) .
REASSEMBL Y
1
2
3
4
5
6
7
8
Strip cable insulation to depth of solder wells
of socket contacts (1).
Slide nut (2) over cable (3).
Slide grommet (4) over cable leads (5).
Insert cable leads (5) into solder wells of
socket contacts (1) and solder.
Push insert (6) into shell assembly (7) from
rear until seated. Groove (8) in insert (6)
must be aligned with guide in shell assembly
(7) to ensure proper fit.
Push socket contacts (1) into insert (6) from
rear until seated.
Push grommet (4) down cable leads (5) an d
over solder wells of socket contacts (1).
Screw nut (2) onto shell assembly (7).
2-2 3