TM 9-2350-238-34-1
FABRIC FUEL CELL DRAININ G
1
2
Use hand pump to remove as much fuel as
possible. Place suitable containers for fue l
under two fabric fuel cell drains (1) (fuel
capacity is 260 gal. (984 I).
Remove two drain plugs (2) and two pre-
formed packings (3) and drain fabric fuel
cell. Allow 24 hours for the fabric fuel cell to
drip, if possible.
REMOVA
L
NOT E
Steps 1 and 2 are written and illus-
trated for left fuel cell access cover
but apply to both the left and right
fuel cell access covers.
1
Remove 20 capscrews (1), 20 Iockwashers
(2), and left fuel cell access cover (3).
2
Remove two capscrews (4) and access cov -
er gasket (5). Reinstall capscrews (4) an d
hand tighten.
2-4 7