TM 9-2350-238-34-1
2-30. MAINTENANCE OF AIR CLEANE R
CENTRIFUGA L FAN .
This task covers :
a. Disassembl y
b. Inspection/Repai r
c. Reassembl y
INITIAL SETU P
Materials/Part s
Air cleaner blower parts kit
Lockwasher (4 )
LockWasher (11)
LockWasher (1 )
Preformed packin g
Preformed packin g
Self-locking nu t
Spring pi n
Reference s
TM 9-2350-238-20- 1
TM 9-2350-238-24P- 1
Equipment Condition s
Air cleaner centrifuga l fan removed (TM 9-2350-238-20-1)
DISASSEMBLY
1
2
3
4
5
Remove machine screw (1), Iockwasher (2) ,
retaining strap (3), and electrical lead (4)
from centrifugal blower motor housing (5) .
Remove ten machine screws (6), te n
Iockwashers (7), and electric motor cover (8)
from centrifugal blower motor housing (5) .
Remove screw (9) and Iockwasher (10 )
securing electrical lead (11) to rear of motor.
Disconnect electrical lead and capacitor (12).
Pull direct current electric motor (13) from
centrifugal blower motor housing (5) .
Remove preformed packing (14). Pul l
electrical leads (11 and 12) from groove
under motor packing flange .
Remove four machine screws (15), four
Iockwashers (16), and lead and capacitor
(12) from centrifugal blower motor housin g
(5) .
2-4 3