Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – Weekly - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
1
WEEKLY
Track Assembly
1. Check for excessive wear thickness on end
connectors. End connector wear thickness should be
greater than 0.125 in. (3.175 mm).
One or more end
connectors worn to less
than 0.125 in. (3.175 mm)
thickness.
2. Check grouser height. Grouser height should be
greater than 0.5 in. (12.7 mm).
Grouser height less than
0.5 in. (12.7 mm).
3. Check for excessive wear thickness on end plates.
End plate thickness should be greater than 0.25 in
(6.35 mm).
Any end plate worn less
than 0.25 in. (6.35 mm).
Figure 1.
Track Assembly.
TM 9-2350-256-10
0099
0099-2