Table 1.
Operator Preventive Maintenance Checks and Services (PMCS) – Weekly - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
3
WEEKLY
Maintenance
Batteries, If
Equipped
WARNING
Remove any rings, bracelets, wristwatches,
and neck chains before working on any
vehicle. Jewelry can catch on equipment
and cause injury, or may short across
electrical circuit and cause severe burns or
electrical shock. Failure to comply may
result in personnel death or injury.
1. Open battery compartment access doors
(WP 0030).
2. Check electrolyte level. Electrolyte level should be to
the ledge in battery filler opening (vent). Caps should
be clean and screwed on tightly.
3. Check that connections are tight and not corroded.
Any corroded or loose
cables or connections.
4. Check that retainers are tight and terminal covers
are present.
5. Check for cracked batteries.
Battery is cracked.
6. Check for indications of batteries boiling over.
Batteries boiling over.
Figure 3.
Maintenance Batteries.
TM 9-2350-256-10
0099
0099-4