TM 9-2350-260-20-1-2
TURBOSUPERCHARGER OIL DRAIN TUBE (RIGHT BANK) REPLACEMENT (Sheet 4 of 4)
10.
Using 5/8 inch wrench, connect generator oil drain check valve (P) to tube (D).
11.
Using 9/16 inch wrench, connect hose (Q) to generator oil drain check valve (P).
12.
Replenish engine oil (LO 9-2350-206-12).
13.
Install generator (page 10-15)
14.
Connect powerplant test (ground hop) equipment (page 5-54).
15.
Start engine and check for leaks.
16.
Disconnect powerplant test (ground hop) equipment (page 5-67).
17.
Install 2A powerplant (page 5-14) or 2D powerplant (page 5-40).
End of Task
TA147513
6-59