TM 9-2350-260-20-1-2
2A ENGINE AND 2D ENGINE POWERPLANT TESTS (GROUND HOP) (Sheet 1 of 16)
NOTE
If you have and choose to use STE/ICE, there are two tests that you can perform:
Test No. 13 (page 4-64) and Test No. 14 (page 4-69).
PROCEDURE INDEX
PROCEDURE
PAGE
Test Hookup
5-54
Idle Test
5-57
Governed No-Load Test
5-58
Stall Test
5-60
Engine Fuel Leak Test
5-65
After-Test Disconnect
5-67
WARNING
Assign one crewmember with a fire extinguisher as fire guard during all
powerplant tests.
WARNING
Take all necessary safety precautions to prevent possible injury to personnel or
damage to equipment.
Stand clear of both transmission output flanges whenever
engine is running.
Hearing protection is required.
Go on to Sheet 2
TA147953
5-52