TM 9-2350-260-20-1-2
2A ENGINE AND 2D ENGINE POWERPLANT TESTS (GROUND HOP) (Sheet 7 of 16)
GOVERNED NO-LOAD TEST:
1.
Start and operate engine until engine oil and transmission oil normal operating temperatures are reached (TM
9-2350-260-10).
WARNING
Take all necessary safety precautions to eliminate possible injury to personnel or
damage to equipment.
Stand clear of both transmission output flanges whenever
engine is running.
Hearing protection is required.
NOTE
An indicator on the linkage shaft and four dots on the body transmission valve
casting indicate shift position.
2.
Be sure transmission is in neutral position by checking shifting position indicator.
If not in neutral position, grasp
shift lever and pull or push lever to set indicator to desired position.
Go on to Sheet 8
TA147958
5-58