MASTER CONTROL PANEL REPAIR (Sheet 47 of 71)
Bilge Pump Switch Lead Assembly and Power Connector Assembly Replacement
(Sheet 2 of 2)
INSTALLATION:
1.
Apply silicone compound (Item 32, Appendix D) to both electrical connectors of lead assembly (A).
2.
Apply silicone compound (Item 32, Appendix D) to three electrical connectors of power connector (C).
3.
Connect lead connector from gas particulate switch (D) circuit 415 to power connector (C).
4.
Connect lead connector from bilge pump circuit breaker (E) circuit 920 to power connector (C).
5.
Connect lead connector (A) circuit 451 to power connector (C).
6.
Connect lead connector (A) circuit 451 to bilge pump switch (B).
7.
Install panel in tank (page 10-56).
End of Task
TA147141
10-109