TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 112 of 783

TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 38 of 71)
Circuit Breaker Replacement (Sheet 2 of 5)
REMOVAL OF CIRCUIT BREAKERS (A, B, C, D, E, and F):
1.
Using fingers, remove two electrical connectors (A)
from circuit breaker (B) by pulling out.
2.
Using screwdriver, remove two screws (C),
lockwashers, and nuts (E) securing circuit breaker
(B) to panel.
Throw lockwashers away.
3.
Remove circuit breaker (B).
Go on to Sheet 3
TA147132
10-100


Back to Top