TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 104 of 783

TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 30 of 71)
Starter Switch Replacement (Sheet 2 of 2)
INSTALLATION:
1.
Position switch(A) and guard (B) onto panel.
2.
Using socket, install nut (C) and new lockwasher (D)
securing switch (A) and guard (B) to pan.
3.
Apply silicone compound (tem 32, Appendix D) to
electrical connectors at rear of switch (C).
4.
Using fingers, connect electrical connectors.
5.
Install master control pane (page 10-56).
End of Task
TA147124
10-92