TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 37 of 71)
Circuit Breaker Replacement (Sheet 1 of 5)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal (A, B, C, D, E, and F (Same)
10-100
Installation (A, B, C, D, E, and F (Same)
10-101
Removal (G)
10-102
Installation (G)
10-103
TOOLS:
Flat-tip screwdriver
Cross-tip screwdriver
11/32 in.
combination and open end wrench
Ratchet with 1/2 in.
drive
3/8 in.
socket with 1/2 in.
drive
SUPPLIES:
Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-42)(14 required)
PRELIMINARY PROCEDURE:
Remove panel from tank (page 10-54)
There are seven circuit breakers located in the master control panel.
Six circuit breaker, fuel shutoff (A), manifold preheat
(B), bilge pump (B), fuel pump (D) utility outlet (E), and IR power (F), are replaced by removing mounting screws from
front of panel.
One circuit breaker, gage (G), is replaced by removing screws from rear of panel.
Go on to Sheet 2
TA147131
10-99