TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 33 of 71)
Bilge Pump Switch and Indicator Light Replacement (Sheet 1 of 4)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
10-95
Installation
10-97
TOOLS:
Flat-tip screwdriver
Cross-tip screwdriver
SUPPLIES:
Silicone compound (Item 32, Appendix D)
Preformed packing (7358626)
Lockwasher (MS35338-42) (4 required)
PRELIMINARY PROCEDURE:
Remove panel from tank (page 10-54)
NOTE
This procedure to be used only if bilge pump switch and indicator light are present
on master control panel.
REMOVAL:
1.
Using
finger,
remove
lens
(A)
by
turning
counterclockwise.
2.
Remove preformed packing (B).
Throw preformed
packing away.
3.
Using fingers, disconnect electrical connector (C)
from base assembly (D).
4.
Using screwdriver, remove two screws (E) and
lockwashers (F) securing base assembly (D) to
panel.
Throw lockwashers away.
5.
Remove base assembly (D).
6.
Using fingers, remove lamp (G) from base assembly
(D).
Go on to Sheet 2
TA147127
10-95