TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 22 of 71)
Master Heater Switch, Hi-Lo Switch, and Indicator Light Replacement
(Sheet 6 of 6)
11. Place switch (Q) and guard (R) in position on panel.
12. Using cross-tip screwdriver, install two screws (S)
and new lockwashers (T) securing switch (Q) to
panel.
13. Apply silicone compound (Item 32, Appendix D) to
two electrical connectors (U).
14. Using fingers, connect two electrical connectors (U)
to switch (Q) by pushing in.
15. Install panel in tank (page 10-56).
End of Task
TA147116
10-84