TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 15 of 71)
Utility Outlet Replacement (Sheet 1 of 2)
TOOLS: Flat-tip screwdriver
Cross-tip screwdriver
SUPPLIES: Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-41)(2 required)
PRELIMINARY PROCEDURE: Remove panel from tank (page 10-54)
REMOVAL:
1.
Using fingers, disconnect electrical connector (A)
from circuit breaker (B).
2.
Using fingers, remove cap (C) by turning
counterclockwise.
3.
Using screwdriver, remove two screws (D) and
lockwashers (E) securing utility outlet assembly (F)
to panel.
Throw lockwashers away.
4.
Remove utility outlet assembly (F), cap (C), and
retainer chain (G).
Go on to Sheet 2
10-77