MASTER CONTROL PANEL REPAIR (Sheet 8 of 71)
IR Power Switch and Indicator Light Replacement (Sheet 4 of 4)
7.
Using screwdriver, install two screws (H) and new lockwashers (J) securing be assembly (G) to panel.
8.
Apply silicone compound (Item 32, Appendix D) to electrical connector (K).
9.
Using fingers, connect electrical connector (K) to
rear of base assembly (G).
10. Place new preformed packing (L) in position on lens
(M).
11. Using fingers, install lens (M) in panel by turning
clockwise.
12. Install panel in tank (page 10-56).
End of Task