MASTER CONTROL PANEL REPAIR (Sheet 4 of 71)
Gas Particulate Switch and Indicator Light Replacement (Sheet 4 of 4)
7.
Using screwdriver, install two screws (J) and new lockwashers (K) securing base assembly (H) to panel.
8.
Apply silicone compound (Item 32, Appendix D) to electrical connector (L).
9.
Using fingers, connect electrical connector (L) to base assembly (H).
10. Place new preformed packing (M) in position on lens (N).
11. Using fingers, install lens (N) in panel by turning clockwise.
12. Install panel in tank (page 10-56).
End of Task