TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 87 of 783

TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 13 of 71)
Blackout Selector Switch Replacement (Sheet 1 of 2)
TOOLS: Flat-tip screwdriver
Cross-tip screwdriver
SUPPLIES: Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-42) (2 required)
PRELIMINARY PROCEDURE:
Remove panel from tank (page 10-54)
REMOVAL:
1.
Using fingers, remove two e
lectrical connectors (A)
and (B) from switch (C).
2.
Using screwdriver, remove two screws (D) and
lockwashers (E) securing switch (C) to panel.
Throw
lockwashers away.
3.
Remove switch (C) from panel.
Go on to Sheet 2
10-75