TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 7 of 71)
IR Power Switch and Indicator Light Replacement (Sheet 3 of 4)
INSTALLATION:
1.
Place switch (A) in position on panel.
2.
Using screwdriver, install two screws (B) and new
lockwashers (C) securing switch (A) to panel.
3.
Apply silicone compound (Item 32, Appendix D) to
two electrical connectors (D) and (E).
4.
Using fingers, connect two electrical connectors (D) and (E) to switch (A) by pushing in
5.
Using finger, install lamp (F) in base assembly (G) by pushing in and turning clockwise.
6.
Place base assembly (G) in position on panel.
Go on to Sheet 4
10-69