TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 3 of 71)
Gas Particulate Switch and Indicator Light Replacement (Sheet 3 of 4)
INSTALLATION:
1.
Place plate (A) and switch (B) in position on panel.
2.
Using screwdriver, install two screws (C) and new lockwashers (D) securing plate (A) and switch (B) to panel.
3.
Apply silicone compound (Item 32, Appendix D) to electrical connector (E) and (F).
4.
Using finger, connect two electrical connectors (E) and (F) to switch (B) by pushing in.
5.
Using fingers, install lamp (G) in base assembly (H) by pushing in and turning clockwise.
6.
Place base assembly (H) in position on panel.
Go on to Sheet 4