TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 59 of 71)
Master Control Panel Power Wiring Harness Replacement (Sheet 6 of 6)
6.
Connect electrical connector (circuit 37) from utility outlet circuit breaker (M).
7.
Connect electrical connector (circuit 76A) from fuel pump circuit breaker (N).
8.
Connect electrical connector (circuit 54) from fuel shutoff circuit breaker (P).
9.
Connect electrical connector (circuit 14) to starter switch (Q).
10.
Connect electrical connectors (circuit 14)(R).
11.
Connect electrical connector (circuit 38/516A) to IR power circuit breaker (S).
12.
Connect electrical connector (circuit 486) to manifold preheat circuit breaker (T).
13.
Connect electrical connector (circuit 27) to gage circuit breaker (U).
14.
Connect electrical connector (circuit 920) to bilge pump circuit breaker (V).
15.
Connect electrical connector (circuit 400) to master heater switch (W).
16.
Connect electrical connector (circuit 459) to master control switch (X).
17.
Install master control panel (page 10-56).
End of task
TA147153
10-121