TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 139 of 783

TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 65 of 71)
Master Control Panel Accessories Wiring Harness Replacement (Sheet 2 of 4)
3.
Disconnect electrical connector (circuit 14) from starter switch connector (E).
4.
Disconnect two electrical connectors (circuits 19 and 514/515) from blackout selector switch (F).
5.
Disconnect two electrical connectors (circuit 519) from hi-beam indicator lamp connectors (G).
6.
Disconnect electrical connector (circuit 516) from IR power indicator lamp (H).
7.
Disconnect two electrical connectors (circuits 516 and 516A) from IR power switch (J).
8.
Disconnect electrical connector (circuit 27) from gage circuit breaker (K).
9.
Disconnect electrical connector (circuit 516A/38) from IR power circuit breaker (L).
10. Remove wiring harness (M) from panel.
Go on to Sheet 3
TA147159
10-127