TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 71 of 71)
Master Control Panel Personnel Heater Wiring Harness Replacement (Sheet 4 of 4)
4.
Place switch (A) and lockring (D) in position on panel.
5.
Using 9/16 inch wrench, install new lockwasher (E) and nuts) securing switch (A) to panel.
6.
Position connector (G) onto panel with key to
edge of panel.
7.
Using screwdriver on screw (H) and 11/32
inch wrench on nut (J), install circuit screws
(H), new lockwashers (K), and nuts (J) to
secure connector (G) to panel.
8.
Apply silicone compound (Item 32, Appendix D) to electrical connector (L) (circuit 400).
9.
Using fingers, connect electrical connector (L) (circuit 400) to switch (M) by pushing in.
10. Install panel in tank (page 10-56).
End of Task
TA147165
10-133