TM 9-2350-260-20-1-3
MASTER CONTROL PANEL REPAIR (Sheet 62 of 71)
Master Control Panel Starting Wiring Harness Replacement (Sheet 3 of 4)
INSTALLATION:
1.
Position connector (A) onto panel with key to edge of panel.
2.
Using screwdriver on screw (B) and 11/32 inch wrench on nut (C), install four screws (B), new lockwashers (D), and
nuts (C) to secure connector (A) to panel.
3.
Apply silicone compound (Item 32, Appendix D) to all electrical connectors of wiring harness (E).
Go on to Sheet 4
TA147156