MASTER CONTROL PANEL REPAIR (Sheet 67 of 71)
Master Control Panel Accessories Wiring Harness Replacement (Sheet 4 of 4)
4.
Connect electrical connector (circuit 516A/38) to IR power circuit breaker (F).
5.
Connect electrical connector (circuit 27) to gage circuit breaker (G).
6.
Connect two electrical connectors (circuits 516 and 516A) to IR power switch (H).
7.
Connect electrical connector (circuit 516) to IR power indicator lamp (J).
8.
Connect two electrical connectors (circuit 519) to hi-beam indicator lamp connectors (K).
9.
Connect two electrical connectors (circuit 19 and 514/515) to blackout selector switch (L).
10. Connect electrical connector (circuit 14) to starter switch connector (M).
11. Install panel in tank (page 10-56).
End of Task