GAS PARTICULATE LEAD REPLACEMENT (Sheet 3 of 5)
6.
Remove bilge pump stowage receptacle plate
(page 10-164).
7.
Remove circuit lead from clamp.
8.
Using wrench, remove screw (J) holding one side of
strap (K).
9.
Using wrench, remove screw (L) holding damp (M).
10. Remove gas particulate air heater lead (N) from
strap (K) and clamp (M).
11. Remove gas particulate lead from tank.
INSTALLATION:
1.
Position gas particulate lead in tank.
2.
Install gas particulate air heater lead (A) under strap
(B) and into clamp (C).
3.
Using wrench, install screw (D) to hold clamp (C).
4.
Using wrench, install screw (E) to hold strap (B).
TA14291
Go on to Sheet 4
10-259