TM-9-2350-261-10

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

OPERATOR'S MANUAL

  TM-9-2350-261-10 - Page 625 of 761

TM 9-2350-261-10
CHECK CARRIER BATTERIES — Continued
0085 00
2.
Check battery retainers and clamp with both hands and try to move them. If batteries move or seem loose, report it to
unit maintenance.
3.
Check battery connections. Try to twist clamp with thumb and first two fingers. Check to see if cables are securely
connected to clamp. If clamp or connection is loose, report it to unit maintenance.
NOTE
Check the water level more frequently in hot weather.
4.
Remove vent plugs from batteries and check battery electrolyte level. Use a flashlight. Look down into each battery
cell. The electrolyte level should be covering the plates and to the lower edge of the vent. If battery cells are low or dry,
add distilled water. Install vent plugs on battery cells.
5.
Clean battery. Wipe off battery casing and surrounding metal parts. Use clean dry wiping rag. Check terminals, clamp,
cables, and retainers for corrosion. If wiping rag will not remove dirt, notify unit maintenance.
6.
Coat terminals with a small amount of grease (GAA).
008500-3