TM 9-2350-261-20-1
CONNECT/DISCONNECT ALTERNATOR (GENERATOR) TEST KIT
0019 00
THIS WORK PACKAGE COVERS:
Connect (page 0019 00-1).
Disconnect (page 0019 00-5).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Alternator Test Kit (WP 0780 00, Item 78)
Electrical Connector Pliers (WP 0780 00, Item 44)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Personnel Required
Unit Mechanic
References
WP 0294 00
Equipment Condition
Engine stopped (see your -10)
Ramp lowered (see your -10)
All radios and heaters turned off (see your -10)
Battery box cover removed (WP 0295 00)
Battery drawer open (WP 0306 00)
CONNECT
CAUTION
If you do not disconnect the battery ground lead, the regulator and alternator test kit may be
damaged when disconnecting and connecting front main wiring harness cannon plugs.
1.
Disconnect battery ground lead (WP 0294 00).
2.
Check all electrical connectors, cannon plugs, and wiring harnesses before connecting alternator test kit.
3.
Remove two front main wiring harness cannon plugs (1) and (2) from voltage regulator (3).
001900-1