TM 9-2350-261-20-1
CONNECT/DISCONNECT ALTERNATOR (GENERATOR) TEST KIT — Continued
0019 00
CAUTION
If ground lead (5) is not connected to chassis and test kit, the alternator could be damaged
when engine is started.
6.
Connect ground lead (5) to terminal 6 (6) of alternator test kit (4) and ground.
a.
Remove screw (7), lockwasher (8), and ground lead (9) from voltage regulator mounting plate (10).
b.
Secure ground lead (5) and ground lead (9) to mounting plate (10) with lockwasher (8) and screw (7).
7.
Connect battery ground lead (WP 0294 00).
0019 00-4