TM 9-2350-261-20-1
200 AMP CHARGING SYSTEM OPERATIONAL CHECK — Continued
0020 00
2Y
1.
Check voltage.
2.
Is voltage 27.5 or higher?
2YN
GO TO
BY
(PAGE 0020 00-2)
3Y
CAUTION
If voltage is 35 or more volts, shut off engine. Alternator
could be damaged.
1.
Raise engine speed slowly.
2.
Is voltage between 27.5 and 28.5 volts?
3YN
GO TO
CY
(PAGE 0020 00-3)
4Y
1.
Run engine at 900 RPM and turn on electrical equipment
(lights and radio).
2.
Does voltage vary less than ± 0.5 volts?
4YN
1.
Go to 200 Amp Charge/Regulation
Troubleshooting (WP 0021 00).
2.
Verify no faults found.
5Y
1.
Verify no faults found.
BY
1.
Adjust voltage regulator setting (WP 0229 00).
2.
Start engine and run at fast idle (800 RPM) with no
electrical equipment/load.
3.
Is voltage higher than battery voltage?
BYN
1.
Go to 200 Amp Charge/Regulation
Troubleshooting (WP 0021 00).
2.
Verify no faults found.
B2Y
1.
Verify no faults found.
002000-2