200 AMP CHARGING SYSTEM OPERATIONAL CHECK
0020 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Multimeter (WP 0780 00, Item 43)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
T
NOTE
On carriers that have standard auxiliary power receptacles,
touch red lead to positive and black lead to negative sockets
in the receptacle.
1.
Turn MASTER SWITCH to ON (see your -10).
2.
Measure battery voltage by placing red lead (1) in positive socket
of NATO plug (2) on auxiliary power (slave) receptacle (3).
Touch negative lead (4) to outside of NATO plug on receptacle.
3.
Is battery voltage more than 24.8 volts?
TN
1.
Replace or charge batteries.
See TM 9-6140-200-14.
2.
Verify no faults found.
Y
1.
Start engine and run at fast idle (800 RPM) with no
electrical equipment/load.
2.
Is voltage higher than battery voltage?
YN
1.
Go to 200 Amp Charge/Regulation
Troubleshooting (WP 0021 00).
2.
Verify no faults found.
002000-1