TM 9-2350-261-20-1
200 AMP FULL FIELD CHARGE TROUBLESHOOTING — Continued
0022 00
2Y
1.
Install cover and six screws on voltage regulator.
2.
Connect alternator test kit (WP 0019 00).
3.
Check capacitors from field to ground (test harness lead
2 to ground) with multimeter.
4.
Does multimeter read between 100,000 ohms and infinity?
2YN
1.
Replace generator (WP 0228 00).
2.
Repeat charging system operational
check (WP 0020 00).
3Y
1.
Check capacitors from field to positive (test harness lead
3 to 4) with multimeter.
2.
Does multimeter read between 100,000 ohms and infinity?
3YN
1.
Replace generator (WP 0228 00).
2.
Repeat charging system operational
check (WP 0020 00).
4Y
1.
Remove alternator test kit (WP 0019 00).
2.
Replace voltage regulator (WP 0230 00).
3.
Repeat charging system operational check (WP 0020 00).
002200-2