TM 9-2350-261-20-1
200 AMP CHARGING SYSTEM OPERATIONAL CHECK — Continued
0020 00
CY
1.
Raise engine speed slowly.
2.
Is voltage below 34 volts?
CYN
1.
Replace voltage regulator
(WP 0230 00).
2.
Verify no faults found.
C2Y
1.
Check voltage.
2.
Does voltage climb to 32 to 34 volts and immediately drop
to battery voltage?
C2YN
GO TO
DY
(PAGE 0020 00-3)
C3Y
1.
Go to 200 Amp Over Voltage Troubleshooting (WP 0023 00).
2.
Verify no faults found.
DY
1.
Check voltage.
2.
Does voltage climb above 28.5 volts but below 33 volts and
remain constant?
DYN
1.
Go to 200 Amp Over Voltage
Troubleshooting (WP 0023 00).
2.
Verify no faults found.
D2Y
1.
Go to 200 Amp Full Field Charge Troubleshooting (WP 0022 00).
2.
Verify no faults found.
0020 00-3/4 blank