TM 9-2350-261-20-1
200 AMP OVER VOLTAGE TROUBLESHOOTING
0023 00
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Alternator Test Kit (WP 0780 00, Item 78)
Electrical Connector Pliers (WP 0780 00, Item 44)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Multimeter (WP 0780 00, Item 43)
Personnel Required
Unit Mechanic
References
See your -10
WP 0229 00
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
T
1.
Turn MASTER SWITCH to ON (see your -10).
2.
Measure battery voltage by placing red lead (1) in positive
socket of NATO plug (2) on auxiliary power (slave)
receptacle (3). Touch black negative lead (4) to outside
of NATO plug on receptacle.
NOTE
On carriers that have standard auxiliary power
receptacles, touch red lead to positive and black lead to
negative sockets in the receptacle.
3.
Adjust voltage regulator (200 amp) to lowest setting
(WP 0229 00).
4.
Start engine and accelerate.
5.
Does voltage climb to 32 to 34 volts and suddenly drop to battery
voltage?
TN
GO TO
BY
(PAGE 0023 00-3)
002300-1