TM 9-2350-261-20-2
REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (ALL EXCEPT
M577A2 AND M1068) — Continued
0218 00
10. Remove four screws (16), washers (17), locknuts (18), and auxiliary power receptacle (11) from master switch panel (6).
Discard locknuts.
11. Remove nut (19) and washer (20) on master switch (21). Remove circuit 50 lead (9) and circuit 49 lead (22) from
master switch terminal (23).
12. Remove nut (24), washer (25), screw (26), and ground lead (14) from instrument panel strut hull mount.
13. Remove gasket (27), insulator (28), and grommet (29) from master switch panel (6). Remove grommet from ground lead
(14). Discard grommet and gasket.
021800-3