TM 9-2350-261-20-2
REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (M577A2 AND
M1068 ONLY) — Continued
0219 00
9.
Place circuit 6 lead (1) in solder well of receptacle (2) and solder lead. Use soldering torch.
10. Place receptacle (2) on hull. Secure with four washers (3), new lockwashers (4), and screws (5).
11. Place circuit 50 lead (6) and clamp (7) on hull weldnut. Secure with washer (8) and screw (9).
12. Install guard (10) on hull. Secure with seven screws (11), new lockwashers (12), and washers (13).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Check receptacle for electrical continuity. Use multimeter.
END OF TASK