REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE (ALL EXCEPT
M577A2 AND M1068) — Continued
0218 00
NOTE
Make sure protective cap retaining cord is attached to receptacle lower mount screw.
9.
Install power receptacle (1) in master switch panel (2). Secure with four screws (3) and nuts (4).
10. Install new grommet (5) on ground lead (6). Route lead out of panel (2). Install grommet in panel.
11. Place lead (6) on instrument panel strut hull mount. Secure with screw (7), washer (8), and nut (9).
12. Install circuit 50 lead (10) on terminal of master switch (11). Secure with new lockwasher (12) and nut (13).
13. Place circuit 49 lead (14) on terminal on lead (10). Secure with screw (15), two washers (16), and nut (17).
021800-5