TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 123 of 1008

TM 9-2350-261-20-2
REPLACE MASTER SWITCH ASSEMBLY — Continued
0221 00
2.
Place knob (13) on master switch (14). Secure with washer (12) and screw (11).
NOTE
Carriers that have 100 amp generators do not have circuit 2A.
3.
Install conductor bus (1) with attached leads and circuit 2A lead (2) on terminal (3). Secure with new lockwasher (4)
and nut (5).
NOTE
On M577A2 and M1068 carriers, do Step 4 then go to Step 6. On all other carriers, after
Step3gotoStep5.
4.
Install circuit 49 lead (6) on master switch terminal (7). Secure with new lockwasher (8) and nut (9).
022100-5