TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (LATE SLAVE RECEPTACLE)
(ALL EXCEPT M577A2 AND M1068) — Continued
0222 00
3.
Remove screw (8), lockwasher (9), and ground lead (10) from negative post (11) of auxiliary power receptacle (12).
Remove ground lead and grommet (13) from master switch panel (6). Discard lockwasher and grommet.
4.
Remove screw (1), locknut (2), circuit 400 lead (3), circuit 2 lead (4), and circuit 6 lead (5) from conductor bus (7).
Remove circuit 6 lead (5) and grommet (8) from master switch panel (9). Discard locknut and grommet.
5.
Remove nut (10), lockwasher (11), and circuit 2A lead (6) from master switch post (12). Discard lockwasher.
6.
Remove screw (13), lockwasher (14), and circuit 49 lead (15) from bus bar (16) of distribution box (17). Remove circuit
49 lead (15) and grommet (18) from distribution box (17). Discard lockwasher and grommet.
0222 00-2